iterative reconstruction algorithm adaptive iterative dose reduction 3d (aidr-3d) Search Results


90
Canon inc fc09 iterative reconstruction
Fc09 Iterative Reconstruction, supplied by Canon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/iterative+reconstruction+algorithm+adaptive+iterative+dose+reduction+3d+%28aidr-3d%29/pmc06609439-73-14-21?v=Canon+inc
Average 90 stars, based on 1 article reviews
fc09 iterative reconstruction - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Canon inc aidr 3d
Examples of cardiac computed tomography scans in two patients with same weight of 60 kg. (A) AIDR 3D with a DLP of 202.1 mGy·cm and CTDIvol of 12.6 mGy, and (B) AiCE with a DLP of 23.3 mGy·cm and CTDIvol of 1.7 mGy. AIDR 3D, adaptive iterative dose reduction three <t>dimensional;</t> DLP, dose-length product; AiCE, advanced intelligent clear-IQ engine.
Aidr 3d, supplied by Canon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/iterative+reconstruction+algorithm+adaptive+iterative+dose+reduction+3d+%28aidr-3d%29/pmc07719916-117-6-9?v=Canon+inc
Average 90 stars, based on 1 article reviews
aidr 3d - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
TOSHIBA Medical aidr 3d algorithm
Overview of scan protocols compared in this study
Aidr 3d Algorithm, supplied by TOSHIBA Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/iterative+reconstruction+algorithm+adaptive+iterative+dose+reduction+3d+%28aidr-3d%29/pmc05606259-80-13-16?v=TOSHIBA+Medical
Average 90 stars, based on 1 article reviews
aidr 3d algorithm - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
TOSHIBA Medical sure exposure controls 3d
CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).
Sure Exposure Controls 3d, supplied by TOSHIBA Medical, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/iterative+reconstruction+algorithm+adaptive+iterative+dose+reduction+3d+%28aidr-3d%29/pmc03955785-141-1-16?v=TOSHIBA+Medical
Average 90 stars, based on 1 article reviews
sure exposure controls 3d - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
Siemens AG iterative reconstruction in image space (iris)
CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).
Iterative Reconstruction In Image Space (Iris), supplied by Siemens AG, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/iterative+reconstruction+algorithm+adaptive+iterative+dose+reduction+3d+%28aidr-3d%29/10__1097_slash_rli__0000000000000172-146-21-30?v=Siemens+AG
Average 90 stars, based on 1 article reviews
iterative reconstruction in image space (iris) - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

86
Toshiba America Electronic Components Inc aidr 3d
CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).
Aidr 3d, supplied by Toshiba America Electronic Components Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/iterative+reconstruction+algorithm+adaptive+iterative+dose+reduction+3d+%28aidr-3d%29/hoffman_john__2018__characterizing_and_minimizing_the_impacts_of_diagnostic_computed_tomography_acquisition_and_reconstruction-1321-15-14?v=Toshiba+America+Electronic+Components+Inc
Average 86 stars, based on 1 article reviews
aidr 3d - by Bioz Stars, 2026-08
86/100 stars
  Buy from Supplier

90
Canon inc hybrid ir aidr 3d enhanced standard with kernel of fc03
CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).
Hybrid Ir Aidr 3d Enhanced Standard With Kernel Of Fc03, supplied by Canon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/iterative+reconstruction+algorithm+adaptive+iterative+dose+reduction+3d+%28aidr-3d%29/pmc10115733-83-20-30?v=Canon+inc
Average 90 stars, based on 1 article reviews
hybrid ir aidr 3d enhanced standard with kernel of fc03 - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

86
Toshiba America Electronic Components Inc iterative dose reconstruction 3d aidr 3d technique
CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).
Iterative Dose Reconstruction 3d Aidr 3d Technique, supplied by Toshiba America Electronic Components Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/iterative+reconstruction+algorithm+adaptive+iterative+dose+reduction+3d+%28aidr-3d%29/10__5812_slash_iranjradiol___134455-47-2-13?v=Toshiba+America+Electronic+Components+Inc
Average 86 stars, based on 1 article reviews
iterative dose reconstruction 3d aidr 3d technique - by Bioz Stars, 2026-08
86/100 stars
  Buy from Supplier

86
Toshiba America Electronic Components Inc reconstruction
CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).
Reconstruction, supplied by Toshiba America Electronic Components Inc, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/iterative+reconstruction+algorithm+adaptive+iterative+dose+reduction+3d+%28aidr-3d%29/hoffman_john__2018__characterizing_and_minimizing_the_impacts_of_diagnostic_computed_tomography_acquisition_and_reconstruction-378-21-22?v=Toshiba+America+Electronic+Components+Inc
Average 86 stars, based on 1 article reviews
reconstruction - by Bioz Stars, 2026-08
86/100 stars
  Buy from Supplier

90
Canon inc reduced-dose ct reconstructed with a hybrid-type ir algorithm
CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).
Reduced Dose Ct Reconstructed With A Hybrid Type Ir Algorithm, supplied by Canon inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/iterative+reconstruction+algorithm+adaptive+iterative+dose+reduction+3d+%28aidr-3d%29/pm30691672-423-41-46?v=Canon+inc
Average 90 stars, based on 1 article reviews
reduced-dose ct reconstructed with a hybrid-type ir algorithm - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

86
Wolters Kluwer Health aidr 3d
CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).
Aidr 3d, supplied by Wolters Kluwer Health, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/iterative+reconstruction+algorithm+adaptive+iterative+dose+reduction+3d+%28aidr-3d%29/10__1097_slash_rct__0000000000000519-105-20-28?v=Wolters+Kluwer+Health
Average 86 stars, based on 1 article reviews
aidr 3d - by Bioz Stars, 2026-08
86/100 stars
  Buy from Supplier

Image Search Results


Examples of cardiac computed tomography scans in two patients with same weight of 60 kg. (A) AIDR 3D with a DLP of 202.1 mGy·cm and CTDIvol of 12.6 mGy, and (B) AiCE with a DLP of 23.3 mGy·cm and CTDIvol of 1.7 mGy. AIDR 3D, adaptive iterative dose reduction three dimensional; DLP, dose-length product; AiCE, advanced intelligent clear-IQ engine.

Journal: Quantitative Imaging in Medicine and Surgery

Article Title: Deep learning reconstruction versus iterative reconstruction for cardiac CT angiography in a stroke imaging protocol: reduced radiation dose and improved image quality

doi: 10.21037/qims-20-626

Figure Lengend Snippet: Examples of cardiac computed tomography scans in two patients with same weight of 60 kg. (A) AIDR 3D with a DLP of 202.1 mGy·cm and CTDIvol of 12.6 mGy, and (B) AiCE with a DLP of 23.3 mGy·cm and CTDIvol of 1.7 mGy. AIDR 3D, adaptive iterative dose reduction three dimensional; DLP, dose-length product; AiCE, advanced intelligent clear-IQ engine.

Article Snippet: Adaptive Iterative Dose Reduction using three Dimensional (AIDR 3D, Canon Medical, Otawara, Japan) was used for the first 148 patients, then DLR with Advanced Intelligent Clear-IQ Engine (AiCE, Canon Medical, Otawara, Japan) for the remaining 148 patients.

Techniques: Computed Tomography

Left atrial appendage thrombus on cardiac computed tomography in two patients with same weight of 60 kg. (A) AIDR 3D with a DLP of 177.3 mGy·cm and CTDIvol of 11.1 mGy, and (B) AiCE with a DLP of 42.1 mGy·cm and CTDIvol of 2.6 mGy. AIDR 3D, adaptive iterative dose reduction three dimensional; DLP, dose-length product; AiCE, advanced intelligent clear-IQ engine.

Journal: Quantitative Imaging in Medicine and Surgery

Article Title: Deep learning reconstruction versus iterative reconstruction for cardiac CT angiography in a stroke imaging protocol: reduced radiation dose and improved image quality

doi: 10.21037/qims-20-626

Figure Lengend Snippet: Left atrial appendage thrombus on cardiac computed tomography in two patients with same weight of 60 kg. (A) AIDR 3D with a DLP of 177.3 mGy·cm and CTDIvol of 11.1 mGy, and (B) AiCE with a DLP of 42.1 mGy·cm and CTDIvol of 2.6 mGy. AIDR 3D, adaptive iterative dose reduction three dimensional; DLP, dose-length product; AiCE, advanced intelligent clear-IQ engine.

Article Snippet: Adaptive Iterative Dose Reduction using three Dimensional (AIDR 3D, Canon Medical, Otawara, Japan) was used for the first 148 patients, then DLR with Advanced Intelligent Clear-IQ Engine (AiCE, Canon Medical, Otawara, Japan) for the remaining 148 patients.

Techniques: Computed Tomography

Box-plots comparing AIDR 3D and AiCE algorithms. (A) Dose-length product (DLP) (mGy·cm), (B) volume computed tomography dose index (CTDIvol) (mGy), (C) effective dose (ED) (mSv). AIDR 3D, adaptive iterative dose reduction three dimensional; AiCE, advanced intelligent clear-IQ engine.

Journal: Quantitative Imaging in Medicine and Surgery

Article Title: Deep learning reconstruction versus iterative reconstruction for cardiac CT angiography in a stroke imaging protocol: reduced radiation dose and improved image quality

doi: 10.21037/qims-20-626

Figure Lengend Snippet: Box-plots comparing AIDR 3D and AiCE algorithms. (A) Dose-length product (DLP) (mGy·cm), (B) volume computed tomography dose index (CTDIvol) (mGy), (C) effective dose (ED) (mSv). AIDR 3D, adaptive iterative dose reduction three dimensional; AiCE, advanced intelligent clear-IQ engine.

Article Snippet: Adaptive Iterative Dose Reduction using three Dimensional (AIDR 3D, Canon Medical, Otawara, Japan) was used for the first 148 patients, then DLR with Advanced Intelligent Clear-IQ Engine (AiCE, Canon Medical, Otawara, Japan) for the remaining 148 patients.

Techniques: Computed Tomography

Overview of scan protocols compared in this study

Journal: Dentomaxillofacial Radiology

Article Title: Reducing the dose of CT of the paranasal sinuses: potential of an iterative reconstruction algorithm

doi: 10.1259/dmfr.20160127

Figure Lengend Snippet: Overview of scan protocols compared in this study

Article Snippet: The images acquired on the Toshiba CT scanner were generated by using the AIDR 3D algorithm (Toshiba Medical Systems, Otawara, Japan).

Techniques:

CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).

Journal: Korean Journal of Radiology

Article Title: Adaptive Iterative Dose Reduction Algorithm in CT: Effect on Image Quality Compared with Filtered Back Projection in Body Phantoms of Different Sizes

doi: 10.3348/kjr.2014.15.2.195

Figure Lengend Snippet: CT image of module 1 of 40-cm phantom reconstructed with adaptive iterative dose reduction three-dimensional standard mode at tube current time product of 180 mAs, showing alignment line (arrows).

Article Snippet: When AIDR 3D is used together with the automatic dose-modulation program ( SURE Exposure controls 3D, Toshiba Medical Systems Corporation), it may simplify the workflow and theoretically it is less concerned with image smoothing together with radiation-dose reduction ( ).

Techniques:

CT images of 40-cm phantom scanned with tube current time product of 180 mAs reconstructed with filtered back projection (A), adaptive iterative dose reduction three-dimensional mild (B), standard (C), and strong modes (D).

Journal: Korean Journal of Radiology

Article Title: Adaptive Iterative Dose Reduction Algorithm in CT: Effect on Image Quality Compared with Filtered Back Projection in Body Phantoms of Different Sizes

doi: 10.3348/kjr.2014.15.2.195

Figure Lengend Snippet: CT images of 40-cm phantom scanned with tube current time product of 180 mAs reconstructed with filtered back projection (A), adaptive iterative dose reduction three-dimensional mild (B), standard (C), and strong modes (D).

Article Snippet: When AIDR 3D is used together with the automatic dose-modulation program ( SURE Exposure controls 3D, Toshiba Medical Systems Corporation), it may simplify the workflow and theoretically it is less concerned with image smoothing together with radiation-dose reduction ( ).

Techniques: